Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.869
Filtrar
1.
BMC Ophthalmol ; 24(1): 87, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38408954

RESUMO

BACKGROUND: To evaluate the difference in anterior chamber depth (ACD) between two eyes among keratoconus patients with binocular very asymmetric ectasia (VAE) and to explore the influencing factors. METHODS: The corneal curvature and ACD in both eyes of patients with VAE were measured by Sirius (version 3.2, CSO, Italy) at the following points: corneal vertex, maximum curvature (apex), and the 1.5 mm, 2.5 mm, and 3.5 mm superior-, inferior-, nasal-, temporal-paracentral from center. The mean pupil power (MPP) and corneal morphology parameters were also measured. Correlations between ACD and curvature and morphology parameters were analyzed by linear regression. RESULTS: 172 eyes of 86 patients (9 to 45 years) were classified into the VAE-N (n = 86) group and the VAE-E group (n = 86) based on the corneal morphology. The central (3.32 ± 0.27 mm versus 3.43 ± 0.29 mm, P < 0.001) and paracentral ACDs increased significantly in the VAE-E group, and the corneal morphology parameters were also significantly higher. The central ACD was significantly correlated with the MPP (r = 0.465), KVf/b (Keratoconus Vertex front/back) (r = 0.306, r = 0.327), and BCVf/b (Baiocchi Calossi Versaci front/back) (r = 0.356, r = 0.416). Linear regression showed good relationships between △ACD and △MPP (R2 = 0.429) and △KVf/b (R2 = 0.504, R2 = 0.536). CONCLUSIONS: The ACD was larger in the VAE-E group. The difference in ACD between the VAE-E and VAE-N groups was significantly correlated with corneal curvature and the extent of corneal elevation, indicating the influences of both the corneal magnification effect and corneal ectasia on ACD.


Assuntos
Ceratocone , Humanos , Ceratocone/complicações , Ceratocone/diagnóstico , Topografia da Córnea , Paquimetria Corneana , Dilatação Patológica , Córnea , Câmara Anterior
2.
Eye Contact Lens ; 50(3): 121-125, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38345011

RESUMO

PURPOSE: Determine the pediatric prevalence of keratoconus (KC) using Scheimpflug corneal tomography. METHODS: A prospective observational study was done on subjects aged 3 to 18 years at the Princeton Vision Clinic, Chicago, IL. Scheimpflug tomography (Pentacam HR, OCULUS Optikgerate GmbH) scans (Belin/Ambrósio Enhanced Ectasia BAD3) yielded BAD Final D (Final D) and Back Elevation at the Thinnest Point (BETP) measurements. Criteria differentiating non-KC from KC suspects & KC were, Non-KC -Final D <2.00 in both eyes; KC suspect -Final D ≥2.00 and <3.00 in combination with BETP ≥18 µm for myopia and ≥28 µm for hyperopia/mixed astigmatism in at least one eye; and KC -Final D of ≥3.00 with BETP ≥18 µm for myopia or ≥28 µm for hyperopia/mixed astigmatism in at least one eye. Two thousand two hundred and six subjects were recorded, removing duplicate and poor-quality scans leaving 2007 subjects. RESULTS: Of 2007 subjects, six were classified as KC -prevalence of 1:334, three subjects were KC suspects -prevalence of 1:669, and total prevalence of KC suspects and KC was 1:223. CONCLUSION: The prevalence of KC in children is higher than previously reported, emphasizing the importance of sensitive screening for KC at its earliest manifestation as standard in pediatric comprehensive eye examinations.


Assuntos
Astigmatismo , Hiperopia , Ceratocone , Miopia , Criança , Humanos , Chicago/epidemiologia , Córnea/diagnóstico por imagem , Paquimetria Corneana , Topografia da Córnea/métodos , Ceratocone/diagnóstico , Ceratocone/epidemiologia , Miopia/diagnóstico , Miopia/epidemiologia , Prevalência , Curva ROC , Tomografia , Estudos Prospectivos
3.
J Cataract Refract Surg ; 50(3): 209-216, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38381615

RESUMO

PURPOSE: To investigate the effects of customized topography-guided epithelium-on crosslinking (epi-on CXL) with oxygen supplementation on procedural efficacy and corrected distance visual acuity (CDVA) in patients with progressive keratoconus (KC) at 1 year. SETTING: Private eye clinic, Brisbane, Australia. DESIGN: Retrospective, single-center, nonrandomized case series. METHODS: Topography-guided epi-on CXL using the Mosaic system was performed on patients with progressive KC. Oxygen goggles; transepithelial riboflavin; and pulsed, high UV-A irradiance (1 second on, 1 second off; 30 mW/cm2) were applied to enhance oxygen kinetics and bioavailabilities of riboflavin and UV-A. Guided by baseline topography, a higher UV-A dose (15 J/cm2) was applied to the area of steepest anterior curvature with decreasing fluence (as low as 7.2 J/cm2) toward the outer 9 mm. Postoperative CDVA and maximum keratometry (Kmax) were evaluated. RESULTS: 102 eyes (80 patients) were followed for 11.5 ± 4.8 months. At the latest follow-up, mean CDVA (logMAR), mean K, and Kmax (diopters [D]) improved from 0.18 ± 0.28, 46.2 ± 3.8, and 53.0 ± 5.67 at baseline to 0.07 ± 0.18, 45.8 ± 3.7, and 51.9 ± 5.56, respectively (P < .001). 3 eyes (3%) lost more than 1 CDVA line, and another 3 eyes (3%) had increased Kmax greater than 2 D. 43 eyes were followed for at least 12 months (n = 43): mean CDVA, mean K, and Kmax improved from 0.19 ± 0.33 logMAR, 46.5 ± 3.5 D, and 53.6 ± 5.67 D to 0.07 ± 0.17 logMAR, 46.0 ± 3.5 D, and 52.33 ± 5.49 D, respectively (P ≤ .002). No complications were observed. CONCLUSIONS: Tailoring oxygen-supplemented epi-on CXL with differential UV-A energy distributions, guided by baseline topography, in patients with KC seems to be safe and effective. At 1 year, study reports sustained improved CDVA and corneal stabilization.


Assuntos
Ceratocone , Fotoquimioterapia , Humanos , Ceratocone/tratamento farmacológico , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Retrospectivos , Raios Ultravioleta , Substância Própria , Topografia da Córnea , Seguimentos , Paquimetria Corneana , Reagentes de Ligações Cruzadas/uso terapêutico , Riboflavina/uso terapêutico , Epitélio
5.
Eye Contact Lens ; 50(3): 138-144, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38181218

RESUMO

OBJECTIVE: To compare the outcomes of corneal tomography obtained with an anterior-to-posterior segment optical coherence tomography device (Revo, Optopol Technologies Sp. z o.o.) and a rotating Scheimpflug camera (Pentacam AXL, Oculus Optikgeräte, Wetzlar, Germany). METHODS: In healthy subjects, agreement in stereometric parameters commonly used in cataract and refractive surgery was assessed. Comparison between the devices was performed using correlation coefficients, the Bland-Altman method, and a paired t test. RESULTS: Results of right eyes of 78 patients (47 women) aged 25.24±5.56 years were analyzed. The flat and steep anterior keratometry values were significantly higher for Revo than Pentacam (43.65±1.58 D vs. 42.99±1.47 D; P = 0.000, and 44.53±1.57 D vs. 43.82±1.49 D; P =0.000, respectively) and showed excellent correlation ( r =0.978 and 0.974, respectively). The results for maximal keratometry manifested a higher difference (45.89±1.69 D vs. 44.27±1.51 D for Revo and Pentacam, P =0.000) but were also strongly correlated ( r =0.871). Revo showed significantly lower corneal thickness values than Pentacam, both for apex pachymetry (535.54±32.45 vs. 550.74±31.55 µm; P =0.000) and for thinnest pachymetry (522.58±32.16 vs. 547.25±31.95 µm; P =0.000). The correlation coefficients for anterior and posterior corneal elevation at the thinnest point showed weak positive correlation ( r =0.179 and 0.185), while the correlation for corneal asphericity was moderate ( r =0.317). CONCLUSIONS: There was a significant difference between keratometric values obtained with Revo and the Pentacam AXL, although the measurements showed excellent correlation. Similar results were found for corneal thickness measurements, but not for corneal surface elevation and corneal asphericity.


Assuntos
Córnea , Tomografia de Coerência Óptica , Humanos , Feminino , Tomografia de Coerência Óptica/métodos , Reprodutibilidade dos Testes , Estudos Prospectivos , Córnea/diagnóstico por imagem , Paquimetria Corneana , Topografia da Córnea/métodos
6.
Am J Ophthalmol ; 259: 185-196, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38211780

RESUMO

PURPOSE: To analyze the corneal biomechanical properties in patients with abnormal corneal tomography (ACT) and predict their stability using the biomechanical stability index (BSI). DESIGN: Prospective cohort study. METHODS: Setting: Multicenter study. STUDY POPULATION: This study included 385 eyes of 278 patients with stable ACT (n = 70), subclinical keratoconus (SKC, n = 65), keratoconus (n = 65), normal controls (NL, n = 142). Forty-three eyes with first-visit ACT were included in a separate cohort (follow-up ACT group). OBSERVATION PROCEDURE: Tomographical and biomechanical parameters (Pentacam and Corvis ST) were recorded. MAIN OUTCOME MEASURES: Nonparametric tests were used for comparison. Logistic regression was employed to introduce BSI to separate stable ACT and SKC accurately. An independent dataset of 43 first-visit ACT eyes was followed up for 1 year to validate BSI's accuracy and positive and negative predictive values (PPV, NPV). RESULTS: The tomographical and biomechanical parameters in patients with Stable ACT remained stable over the follow-up period (12.73 ± 2.57 months, P > .05). Stable ACT had 12/14 biomechanical parameters different (P < .05) from SKC but not different from NL (P > .05). With a cut-off value of 0.585, BSI demonstrated the strongest ability to distinguish between stable ACT and SKC (area under the receiver operating characteristic curve = 0.991), with 93.85% sensitivity and 97.14% specificity. During the 1-year follow-up of 43 eyes (follow-up ACT group), 30 remained stable. The accuracy, PPV, and NPV of the BSI were 95.35%, 100%, and 93.75%, respectively. CONCLUSIONS: Biomechanical properties of patients with stable abnormal tomography corneas were stronger than SKC and close to normal corneas, which may explain the reason for tomographic stability. The BSI may be useful for predicting disease progression in patients with ACT and the possible management of corneal cross-linking at the first visit.


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico , Córnea/diagnóstico por imagem , Topografia da Córnea/métodos , Estudos Prospectivos , Curva ROC , Prognóstico , Fenômenos Biomecânicos , Paquimetria Corneana/métodos
7.
Clin Exp Optom ; 107(1): 32-39, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37121670

RESUMO

CLINICAL RELEVANCE: Accurate thickness measurement of corneal layers using anterior segment OCT can be used to improve visual outcomes. Understanding its applications is essential for optometric practices to enhance eye care procedures. BACKGROUND: To evaluate the thicknesses of different corneal layers for identifying keratoconus (KCN) and subclinical keratoconus (SKCN) using spectral-domain optical coherence tomography (SD-OCT). METHODS: This prospective study analyzed 60 eyes with KCN, 48 eyes with SKCN, and 53 normal eyes. The central corneal thickness (CCT) and thicknesses of the epithelium, Bowman, stroma, and Descemet-endothelium layers were measured using SD-OCT. One way analysis of variance and the area under the curve (AUC) were used to evaluate the parameters. The Delong method was used to compare AUCs. RESULTS: In KCN, CCT and thicknesses of epithelium, Bowman, stroma, and Descemet-endothelium layers were 495.5 ± 41.7, 52.6 ± 6.4,11.5 ± 1.4, 415.5 ± 38.9, and 12.3 ± 1.7 µm, respectively. These thickness values were respectively 524.5 ± 33.3, 56.8 ± 6.8, 11.5 ± 1.6, 439.8 ± 30.6, and 12.4 ± 1.7 µm in SKCN and 563.8 ± 37.9, 57.7 ± 6.9, 12.2 ± 1.6, 469.5 ± 33.7, and 12.8 ± 2.1µm in normal group. Total cornea and stroma in KCN and SKCN, and epithelium in KCN were significantly thinner compared to the normal group (P < 0.001). The highest AUC values were observed for CCT in KCN (AUC 0.90) and SKCN (AUC 0.782). The diagnostic accuracy was significantly higher for stromal thickness in KCN (sensitivity 81.7%, specificity 73.6%, AUC 0.871) and SKCN (sensitivity 80.0%, specificity 56.6%, AUC 0.751) than other individual corneal layers (Delong, P < 0.001) . CONCLUSION: CCT can accurately distinguish keratoconus from normal eyes. However, central corneal stromal thinning was the most sensitive diagnostic index for early detection of SKCN. Developing standardized stromal maps may be helpful for detecting SKCN.


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Estudos Prospectivos , Córnea/diagnóstico por imagem , Topografia da Córnea , Paquimetria Corneana
8.
J Pediatr Ophthalmol Strabismus ; 61(1): 44-50, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37227009

RESUMO

PURPOSE: To evaluate the clinical characteristics of pediatric patients with progression of keratoconus after accelerated iontophoresis-assisted epithelium-on corneal cross-linking (I-ON CXL) and to assess the efficacy and safety of re-treatment using accelerated epithelium-off CXL (epi-OFF CXL). METHODS: Sixteen eyes of 16 patients (mean age: 14.6 ± 2.5 years) with keratoconus underwent I-ON CXL. The main outcome measures were uncorrected distance visual acuity, corrected distance visual acuity, maximum keratometry index (Kmax), minimum corneal thickness, elevation front and elevation back measured at the thinnest point, total higher order aberrations root main square (HOA RMS), coma RMS, and spherical aberration. An increment of Kmax greater than 1.00 diopter (D) and a decrease of greater than 20 µm in pachymetry were considered to determine the progression of keratoconus. Patients with progression of keratoconus after I-ON CXL were re-treated using an epi-OFF CXL protocol. RESULTS: Two years after I-ON CXL, 12 patients showed progression of keratoconus, whereas 4 patients were stable. There was significant worsening of Kmax (P = .04) and steepest keratometric reading (P = .01). Furthermore, a significant correlation was documented between progression of keratoconus and age (P = .02). These patients were re-treated using an epi-OFF protocol and after 2 years all patients were stable, and a statistically significant reduction of the mean Kmax (P = .007), HOA RMS (P = .05), and coma RMS (P = 05) was observed. CONCLUSIONS: I-ON CXL was ineffective in the treatment of pediatric keratoconus in younger children, whereas it had an efficacy of 2 years in older children. Re-treatment using epi-OFF CXL proved effective to halt progression of keratoconus after I-ON CXL failure. [J Pediatr Ophthalmol Strabismus. 2024;61(1):44-50.].


Assuntos
Ceratocone , Fotoquimioterapia , Humanos , Criança , Adolescente , Ceratocone/diagnóstico , Ceratocone/tratamento farmacológico , Crosslinking Corneano , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Iontoforese/métodos , Raios Ultravioleta , Coma/tratamento farmacológico , Riboflavina/uso terapêutico , Topografia da Córnea/métodos , Paquimetria Corneana , Reagentes de Ligações Cruzadas/uso terapêutico , Colágeno
9.
J Fr Ophtalmol ; 47(1): 103792, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37087321

RESUMO

PURPOSE: To investigate changes in topometric corneal indices and proclivity toward corneal ectasia, as well as keratometric indices and anterior chamber dimensions in palpebral vernal keratoconjunctivitis (VKC). METHODS: This study included 80 patients with clinically established symptoms of grade 0 or grade 1 palpebral VKC (group 1) and 66 healthy participants (group 2). After a comprehensive ophthalmic examination including best-corrected visual acuity, intraocular pressure measurements and slit-lamp biomicroscopy, pachymetric indices and anterior chamber dimensions were measured using the Pentacam HR rotating Scheimpflug device. Topometric indices, which are particularly useful for determining proclivity toward corneal ectasia, were extracted from a topometric map. RESULTS: In groups 1 and 2, the mean ages were 13.11±5.22 and 16.45±5.09 years, respectively. The mean age at disease onset in group 1 was 10.09±5.03 years, and the mean disease duration was 36.23±8.43 months. Group 1 had significantly higher mean topometric indices than group 2, particularly the index of surface variance (P=0.001), index of vertical asymmetry (P=0.007), center keratoconus index (P=0.050), and Belin/Ambrosio enhanced ectasia total deviation value (P=0.032). Mean posterior corneal astigmatism differed significantly between groups 1 and 2 (P=0.003). CONCLUSIONS: Significantly higher mean topometric indices in VKC indicate a proclivity for corneal ectasia, which could be attributed to general changes in the corneal ultrastructure caused by persistent itching-induced eye rubbing.


Assuntos
Conjuntivite Alérgica , Ceratocone , Humanos , Criança , Adolescente , Conjuntivite Alérgica/complicações , Conjuntivite Alérgica/diagnóstico , Conjuntivite Alérgica/epidemiologia , Dilatação Patológica/complicações , Dilatação Patológica/diagnóstico , Topografia da Córnea/métodos , Acuidade Visual , Córnea , Ceratocone/complicações , Ceratocone/diagnóstico , Paquimetria Corneana
10.
Clin Exp Ophthalmol ; 52(1): 22-30, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37963802

RESUMO

BACKGROUND: This study investigated the prevalence, risk factors and severity of corneal tomographic features of keratoconus in Down syndrome (DS). Additionally, previous studies indicate anomalous corneal features in DS, without keratoconus, this study characterised corneal features in DS without keratoconus. METHODS: This prospective observational study included participants with DS ≥10 years old. Keratoconus diagnosis, risk factors and corneal tomographic characteristics were recorded. Participants underwent slit-lamp biomicroscopy, Scheimpflug corneal tomography, corneal topography and autorefraction. A diagnosis of keratoconus (DS-KC), suspect keratoconus (DS-SK) and non-keratoconus (DS-NK) was made based on expert review of scans by three fellowship trained anterior segment ophthalmologists. Corneal tomography parameters from one eye of each participant were analysed. RESULTS: Keratoconus affected 50 (26.3%) of 190 participants, diagnosed by corneal tomography, topography or slit-lamp signs. Corneal hydrops affected 14.0% of DS-KC participants. Eye rubbing was a significant risk factor for keratoconus (p = 0.036). 175 (92%) participants could undertake corneal tomography of which tomography assessment alone identified 47 (26.9%) DS-KC participants, 64 (36.6%) DS-SK participants and 64 (36.6%) DS-NK participants. Significant differences (p < 0.001) were identified when the DS-KC, DS-SK and DS-NK groups were compared in maximum keratometry and posterior elevation at the thinnest point respectively: median (interquartile range) 50.20 (10.30D), 47.60 (1.95D), 46.50 (2.40D); 24.0 (38.00 µm), 10.00 (13.75 µm), 8.00 (6.00 µm). The DS-SK and DS-NK cohorts had similar minimum pachymetry, however, had several significantly different parameters among which included greater maximum keratometry, posterior elevation at the thinnest point in the DS-SK group. CONCLUSIONS: Keratoconus is common in DS. Keratoconus screening with corneal tomography is recommended for early detection.


Assuntos
Síndrome de Down , Ceratocone , Criança , Humanos , Córnea/diagnóstico por imagem , Paquimetria Corneana , Topografia da Córnea/métodos , Síndrome de Down/complicações , Síndrome de Down/diagnóstico , Síndrome de Down/epidemiologia , Ceratocone/complicações , Ceratocone/diagnóstico , Ceratocone/epidemiologia , Prevalência , Fatores de Risco , Tomografia , Estudos Prospectivos
11.
Ophthalmology ; 131(1): 107-121, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37855776

RESUMO

PURPOSE: To review the published literature on the diagnostic capabilities of the newest generation of corneal imaging devices for the identification of keratoconus. METHODS: Corneal imaging devices studied included tomographic platforms (Scheimpflug photography, OCT) and functional biomechanical devices (imaging an air impulse on the cornea). A literature search in the PubMed database for English language studies was last conducted in February 2023. The search yielded 469 citations, which were reviewed in abstract form. Of these, 147 were relevant to the assessment objectives and underwent full-text review. Forty-five articles met the criteria for inclusion and were assigned a level of evidence rating by the panel methodologist. Twenty-six articles were rated level II, and 19 articles were rated level III. There were no level I evidence studies of corneal imaging for the diagnosis of keratoconus found in the literature. To provide a common cross-study outcome measure, diagnostic sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were extracted. (A perfect diagnostic test that identifies all cases properly has an AUC of 1.0.) RESULTS: For the detection of keratoconus, sensitivities for all devices and parameters (e.g., anterior or posterior corneal curvature, corneal thickness) ranged from 65% to 100%. The majority of studies and parameters had sensitivities greater than 90%. The AUCs ranged from 0.82 to 1.00, with the majority greater than 0.90. Combined indices that integrated multiple parameters had an AUC in the mid-0.90 range. Keratoconus suspect detection performance was lower with AUCs ranging from 0.66 to 0.99, but most devices and parameters had sensitivities less than 90%. CONCLUSIONS: Modern corneal imaging devices provide improved characterization of the cornea and are accurate in detecting keratoconus with high AUCs ranging from 0.82 to 1.00. The detection of keratoconus suspects is less accurate with AUCs ranging from 0.66 to 0.99. Parameters based on single anatomic locations had a wide range of AUCs. Studies with combined indices using more data and parameters consistently reported high AUCs. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Ceratocone , Oftalmologia , Humanos , Córnea/diagnóstico por imagem , Paquimetria Corneana/métodos , Topografia da Córnea/métodos , Ceratocone/diagnóstico por imagem , Curva ROC , Tomografia
12.
Graefes Arch Clin Exp Ophthalmol ; 262(1): 143-148, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37493776

RESUMO

PURPOSE: To compare corneal tomographic parameters between Hispanic White and non-Hispanic White patients using Pentacam data. METHODS: This retrospective study evaluated preoperative Pentacam data from 641 patients 50 years or older who underwent surgery for senile cataract and self-identified as Hispanic or non-Hispanic White. Patients of non-White race or multiethnic groups, or a history of surgery, trauma, or any abnormality of the cornea or anterior segment were excluded. Cornea and anterior segment parameters, as measured with Pentacam, were then compared between Hispanics and non-Hispanics. RESULTS: There were 352 Hispanic White and 289 non-Hispanic White patients. These included 231 men and 410 women, with a mean age of 69.5 ± 8.2 years. There were no significant differences between Hispanics and non-Hispanics in front or back keratometry or amount of front astigmatism. However, Hispanics had a greater amount of back astigmatism (0.36 ± 0.19 vs 0.32 ± 0.17 diopter, P = 0.04). Moreover, there was a statistically significant difference in front steep axis of the left eyes between Hispanics and non-Hispanics (97.8 ± 47.9 vs 108.2 ± 48.9 deg, P = 0.01), and a marginally significant difference in front steep axis of the right eyes (81.0 ± 48.2 vs 73.5 ± 49.9 deg, P = 0.06). Hispanics also had a lower vertex pachymetry (548.1 ± 34.5 vs 553.4 ± 37.4 µm, P = 0.04) and a smaller anterior chamber volume (134.7 ± 39.0 vs 146.1 ± 39.9 mm3, P < 0.001). CONCLUSIONS: There are some differences in cornea and anterior segment parameters between Hispanics and non-Hispanics 50 years or older who underwent surgery for senile cataract. However, such differences may not be clinically significant.


Assuntos
Astigmatismo , Catarata , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Topografia da Córnea/métodos , Córnea , Catarata/diagnóstico , Paquimetria Corneana
13.
Cont Lens Anterior Eye ; 47(1): 102100, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38072740

RESUMO

PURPOSE: To investigate the alterations in corneal biomechanical metrics induced by orthokeratology (ortho-k) using Corvis ST and to determine the factors influencing these changes. METHOD: A prospective observational study was conducted to analyze various Corvis ST parameters in 32 children with low to moderate myopia who successfully underwent ortho-k lens fitting. Corneal biomechanical measurements via Corvis ST were acquired at six distinct time points: baseline (pre) and 2 h (pos2h), 6 h (pos6h), and 10 h (pos10h) following the removal of the first overnight wear ortho-k, one week (pos1w) and one month (pos1m) subsequent to the initiation of ortho-k. RESULT: Significant differences were observed in Corvis ST Biomechanical parameters DAR2, IIR, CBI, and cCBI post ortho-k intervention. The integration of covariates (CCT, SimK, and bIOP) mitigated the differences in DAR2, IIR, and cCBI, but not in CBI. Initially, the stiffness parameter at first applanation, SP-A1, did not demonstrate significant variations, but after adjusting for covariates, noticeable differences over time were observed. The Stress-Strain Indeces, SSIv1 and SSIv2, did not manifest considerable changes over time, irrespective of the adjustment for covariates. No significant disparities were identified among different ortho-k lens brands. CONCLUSION: Corneal biomechanics remained consistent throughout the one-month period of ortho-k lens wear. The observed changes in Corvis ST parameters subsequent ortho-k are primarily attributable to alterations in corneal pachymetry and morphology, rather than actual alterations in corneal biomechanics. The stability of corneal biomechanics post ortho-k treatment suggests the safety of this approach for adolescents from a corneal biomechanics perspective.


Assuntos
Córnea , Tonometria Ocular , Adolescente , Criança , Humanos , Fenômenos Biomecânicos , Paquimetria Corneana , Topografia da Córnea
14.
Eur J Ophthalmol ; 34(1): 59-70, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37731321

RESUMO

PURPOSE: To determine the sensitive indices distinguishing forme-fruste keratoconus (FFKC) and early keratoconus (early KC) from thin normal corneas, and their cutoff values using Sirius topography. METHODS: 156 eyes with normal thin corneas < 500 um (group 1), 99 eyes with early KC (group 2) and 41 eyes with FFKC (group 3), were assessed retrospectively for: corneal keratometric indices, pachymetry indices, corneal aberrations, elevation indices; thinnest corneal point elevation, Q value, root mean square (RMS) withRMS/ area (RMS/A); and KC summary indices of front and back surfaces; surface asymmetry index (SIf, SIb), elevation at KC vertex (KVf, KVb), Baiocchi-Calossi-Versaci index (BCVf, BCVb) and summation of its vector (BCV). Cutoff values were calculated. RESULTS: Keratometry indices were significantly different between early KC and thin normal cases (apex front curvature had the highest area-under-the-ROC-curve (AUROC) (0.926) in early KC, while only apex curvature and coordinates were significant in FFKC cases. Pachymetry indices did not show any significance in differentiating either early KC or FFKC from normal thin corneas. KC summary indices were highly significant among the 3 groups. The highest AUROC was observed with KVb in early KC (0.987) and with KVf in FFKC (0.831). Vertical coma and vertical trefoil showed the highest significance of all aberration parameters differentiating the 3 groups. Thinnest point elevation, RMS and RMS/A showed the highest AUROC in differentiating early KC and FFKC cases from thin normal corneas. CONCLUSION: Comparing early KC and FFKC to thin normal corneas, Sirius provided high precision in prediction.


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico , Topografia da Córnea , Estudos Retrospectivos , Córnea , Curva ROC , Paquimetria Corneana
15.
Ophthalmology ; 131(3): 310-321, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37839561

RESUMO

PURPOSE: To characterize focal biomechanical alterations in subclinical keratoconus (SKC) using motion-tracking (MT) Brillouin microscopy and evaluate the ability of MT Brillouin metrics to differentiate eyes with SKC from normal control eyes. DESIGN: Prospective cross-sectional study. PARTICIPANTS: Thirty eyes from 30 patients were evaluated, including 15 eyes from 15 bilaterally normal patients and 15 eyes with SKC from 15 patients. METHODS: All patients underwent Scheimpflug tomography and MT Brillouin microscopy using a custom-built device. Mean and minimum MT Brillouin values within the anterior plateau region and anterior 150 µm were generated. Scheimpflug metrics evaluated included inferior-superior (IS) value, maximum keratometry (Kmax), thinnest corneal thickness, asymmetry indices, Belin/Ambrosio display total deviation, and Ambrosio relational thickness. Receiver operating characteristic (ROC) curves were generated for all Scheimpflug and MT Brillouin metrics evaluated to determine the area under the ROC curve (AUC), sensitivity, and specificity for each variable. MAIN OUTCOME MEASURES: Discriminative performance based on AUC, sensitivity, and specificity. RESULTS: No significant differences were found between groups for age, sex, manifest refraction spherical equivalent, corrected distance visual acuity, Kmax, or KISA% index. Among Scheimpflug metrics, significant differences were found between groups for thinnest corneal thickness (556 µm vs. 522 µm; P < 0.001), IS value (0.29 diopter [D] vs. 1.05 D; P < 0.001), index of vertical asymmetry (IVA; 0.10 vs. 0.19; P < 0.001), and keratoconus index (1.01 vs. 1.05; P < 0.001), and no significant differences were found for any other Scheimpflug metric. Among MT Brillouin metrics, clear differences were found between control eyes and eyes with SKC for mean plateau (5.71 GHz vs. 5.68 GHz; P < 0.0001), minimum plateau (5.69 GHz vs. 5.65 GHz; P < 0.0001), mean anterior 150 µm (5.72 GHz vs. 5.68 GHz; P < 0.0001), and minimum anterior 150 µm (5.70 GHz vs. 5.66 GHz; P < 0.001). All MT Brillouin plateau and anterior 150 µm mean and minimum metrics fully differentiated groups (AUC, 1.0 for each), whereas the best performing Scheimpflug metrics were keratoconus index (AUC, 0.91), IS value (AUC, 0.89), and IVA (AUC, 0.88). CONCLUSIONS: Motion-tracking Brillouin microscopy metrics effectively characterize focal corneal biomechanical alterations in eyes with SKC and clearly differentiated these eyes from control eyes, including eyes that were not differentiated accurately using Scheimpflug metrics. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico , Topografia da Córnea/métodos , Microscopia , Estudos Transversais , Estudos Prospectivos , Paquimetria Corneana
16.
Indian J Ophthalmol ; 72(4): 533-537, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38099366

RESUMO

PURPOSE: To evaluate the factors affecting corneal deformation amplitude (DA) measured using Corvis ST in eyes with open-angle glaucoma. METHODS: This prospective, longitudinal study included 48 eyes with open-angle glaucoma who required additional intraocular pressure (IOP)-lowering drops. All eyes underwent a complete eye examination at baseline, including a Corvis ST, which was repeated 4-8 weeks after the change in therapy. Factors affecting the corneal biomechanics, namely the DA, were determined using mixed effect models. RESULTS: The mean age of the cohort was 65.0 ± 7.9 years. The mean IOP reduced from 23.4 ± 5.4 mmHg to 17.9 ± 5 mmHg after the change in glaucoma treatment ( P < 0.001). The DA increased from 0.89 ± 0.16 mm to 1.00 ± 0.13 mm after IOP reduction ( P < 0.001). On mixed effect model analysis, IOP (-0.02 ± 0.001, P < 0.001) and corneal pachymetry (-0.0003 ± 0.0001, P = 0.02) affected the change in the DA. CONCLUSION: IOP and corneal pachymetry affect the DA and must be accounted for when using Corvis ST to evaluate corneal biomechanics in glaucoma.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Humanos , Pessoa de Meia-Idade , Idoso , Glaucoma de Ângulo Aberto/diagnóstico , Estudos Prospectivos , Estudos Longitudinais , Córnea , Pressão Intraocular , Tonometria Ocular , Paquimetria Corneana , Fenômenos Biomecânicos
17.
Cornea ; 43(1): 59-62, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36728315

RESUMO

PURPOSE: The aim of this study was to provide normative databases of Fourier analysis (FA) and Belin-Ambrósio enhanced ectasia display (BAD) in healthy White 4-year-old emmetropic children. METHODS: FA parameters analyzed were spherical component (SRmin), spherical eccentricity (SEcc), maximal decentration (MD), regular astigmatism at the center (Astigm. C) and periphery (Astigm. P), and irregularity (I). The parameters obtained by BAD included summary indicator BAD D, anterior corneal curvature (K1 and K2, D), maximal keratometry (Kmax, D), maximal Ambrósio relational thinnest (ART max), and pachymetric and BAD indices. RESULTS: Eighty-nine eyes of eighty-nine 4-year-old children were included. The mean values of FA parameters were the following: SRmin 7.77, SEcc 0.600, MD 0.160, Astigm. C 0.070, Astigm. P 0.050, and I 0.019. The mean K1 and K2 in our study group were 42.92 ± 1.29 D and 43.75 ± 1.41 D, with the mean BAD D value 0.42 ± 0.67. The mean PPI min 0.629 ± 0.117, PPI max 1.059 ± 0.155, PPI avg 0.847 ± 0.103, Kmax 44.10 ± 1.39, and median of ART max 515.0 were recorded. No statistically significant differences between male and female sex in any of FA or BAD parameters were found. CONCLUSIONS: This is the first study providing large normative data on FA and BAD in 4-year-old White emmetropic children. We proposed a cutoff D value for early ectasia and clinical keratoconus in 4-year-old children.


Assuntos
Córnea , Emetropia , Ceratocone , Pré-Escolar , Feminino , Humanos , Masculino , Paquimetria Corneana , Topografia da Córnea , Dilatação Patológica , Curva ROC , População Branca
18.
PLoS One ; 18(12): e0295434, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38127965

RESUMO

PURPOSE: The long-term clinical outcomes, postoperative complications, and graft survival of Descemet-membrane endothelial keratoplasty (DMEK) remain poorly understood. We retrospectively assessed these variables in all consecutive eyes that underwent DMEK for any indication in 2014-2018. The findings were compared to the long-term DMEK studies of five other groups (3-10-year follow-up). METHODS: Patients underwent ophthalmological tests preoperatively, at 1, 3, 6, and 12 postoperative months, and then annually. Five-year graft survival was determined by Kaplan-Meier estimator. Change in best-corrected visual acuity (BCVA), endothelial-cell density (ECD), and central-corneal thickness (CCT) at each timepoint was determined. RESULTS: 107 eyes (80 patients; 72 years old; 67% female) underwent first-time DMEK for uncomplicated Fuchs endothelial corneal dystrophy (94% of eyes), pseudophakic bullous keratopathy (3%), and regraft after previous keratoplasty (3%). The most common complication was graft detachment requiring rebubbling (18%). Thirteen grafts (12%) failed at ≤15 months. Cumulative 5-year graft-survival probability was 88% (95% confidence intervals = 79-94%). BCVA improved from 0.6 logMAR preoperatively to 0.05 logMAR at 1 year (p<0.0001) and then remained stable. Donor ECD dropped by 47% at 6 postoperative months and then continued to decrease by 4.0%/year. Five-year endothelial-cell loss was 65% (from 2550 to 900 cells/mm2). CCT dropped from 618 to 551 µm at 5 years (p<0.0001). These findings are generally consistent with previous long-term DMEK studies. CONCLUSIONS: DMEK has low complication and high graft-survival rates and excellent clinical outcomes that persist up to 5 years post-surgery. DMEK seems to be a safe and effective treatment in the long term.


Assuntos
Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Distrofia Endotelial de Fuchs , Humanos , Feminino , Idoso , Masculino , Endotélio Corneano/cirurgia , Estudos Retrospectivos , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/efeitos adversos , Paquimetria Corneana , Contagem de Células , Acuidade Visual , Distrofia Endotelial de Fuchs/cirurgia , Sobrevivência de Enxerto , Lâmina Limitante Posterior/cirurgia
19.
BMC Ophthalmol ; 23(1): 459, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37968616

RESUMO

BACKGROUND: The diagnosis of keratoconus, as the most prevalent corneal ectatic disorder, at the subclinical stage gained great attention due to the increased acceptance of refractive surgeries. This study aimed to assess the pattern of the corneal biomechanical properties derived from Corneal Visualization Scheimpflug Technology (Corvis ST) and evaluate the diagnostic value of these parameters in distinguishing subclinical keratoconus (SKC) from normal eyes. METHODS: This prospective study was conducted on 73 SKC and 69 normal eyes. Subclinical keratoconus eyes were defined as corneas with no clinical evidence of keratoconus and suspicious topographic and tomographic features. Following a complete ophthalmic examination, topographic and tomographic corneal assessment via Pentacam HR, and corneal biomechanical evaluation utilizing Corvis ST were done. RESULTS: Subclinical keratoconus eyes presented significantly higher Deformation Amplitude (DA) ratio, Tomographic Biomechanical Index (TBI), and Corvis Biomechanical Index (CBI) rates than the control group. Conversely, Ambrósio Relational Thickness to the Horizontal profile (ARTh), and Stiffness Parameter at the first Applanation (SPA1) showed significantly lower rates in SKC eyes. In diagnosing SKC from normal eyes, TBI (AUC: 0.858, Cut-off value: > 0.33, Youden index: 0.55), ARTh (AUC: 0.813, Cut-off value: ≤ 488.1, Youden index: 0.58), and CBI (AUC: 0.804, Cut-off value: > 0.47, Youden index: 0.49) appeared as good indicators. CONCLUSIONS: TBI, CBI, and ARTh parameters could be valuable in distinguishing SKC eyes from normal ones.


Assuntos
Ceratocone , Procedimentos Cirúrgicos Refrativos , Humanos , Ceratocone/diagnóstico , Ceratocone/cirurgia , Fenômenos Biomecânicos , Estudos Prospectivos , Córnea/cirurgia , Topografia da Córnea/métodos , Curva ROC , Paquimetria Corneana/métodos , Estudos Retrospectivos
20.
Asia Pac J Ophthalmol (Phila) ; 12(6): 574-581, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37973045

RESUMO

PURPOSE: This study aimed to develop a novel method to diagnose early keratoconus by detecting localized corneal biomechanical changes based on dynamic deformation videos using machine learning. DESIGN: Diagnostic research study. METHODS: We included 917 corneal videos from the Tianjin Eye Hospital (Tianjin, China) and Shanxi Eye Hospital (Xi'an, China) from February 6, 2015, to August 25, 2022. Scheimpflug technology was used to obtain dynamic deformation videos under forced puffs of air. Fourteen new pixel-level biomechanical parameters were calculated based on a spline curve equation fitting by 115,200-pixel points from the corneal contour extracted from videos to characterize localized biomechanics. An ensemble learning model was developed, external validation was performed, and the diagnostic performance was compared with that of existing clinical diagnostic indices. The performance of the developed machine learning model was evaluated using precision, recall, F1 score, and the area under the receiver operating characteristic curve. RESULTS: The ensemble learning model successfully diagnosed early keratoconus (area under the curve = 0.9997) with 95.73% precision, 95.61% recall, and 95.50% F1 score in the sample set (n=802). External validation on an independent dataset (n=115) achieved 91.38% precision, 92.11% recall, and 91.18% F1 score. Diagnostic accuracy was significantly better than that of existing clinical diagnostic indices (from 86.28% to 93.36%, all P <0.01). CONCLUSIONS: Localized corneal biomechanical changes detected using dynamic deformation videos combined with machine learning algorithms were useful for diagnosing early keratoconus. Focusing on localized biomechanical changes may guide ophthalmologists, aiding the timely diagnosis of early keratoconus and benefiting the patient's vision.


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico , Inteligência Artificial , Topografia da Córnea/métodos , Córnea , Curva ROC , Fenômenos Biomecânicos , Estudos Retrospectivos , Paquimetria Corneana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...